SECURE ONLINE CHECKOUT
First Fence Logo
  
Same & Next Day Delivery
  
24/7 Sales Line
Strong approved UK Supply Chain
  
Locations Nationwide
  
Competitive Pricing

HD/K-150 - Heavy Duty Load Bearing Cavity Wall Lintel

SKU: WEB-01279
Images shown are for illustration purposes only and may differ slightly
ProductQtyPrice (ea)Total
Goods Total
Overall Quantity:
0
Total:
£0.00
£0.00
Inner Leaf Width100
Outer Leaf Width95

Specification

Inner Leaf Width100
Outer Leaf Width95

Downloads

HD/K-150 - Heavy Duty Load Bearing Cavity Wall Lintel

This heavy duty load bearing lintel is suitable for bearing heavier loads than a standard lintel and has been designed for use with cavity gaps between 150mm and 165mm. The lintel has an outer leaf width of 95mm but is able to support bricks with a width up to 102mm (95mm leaf width + 7mm overhang). The inner leaf has a width of 100mm and is able to support blocks of the same width.

The HD/K-150 heavy duty lintels are available in 150mm increments starting at 750mm up to 4050mm which allows for the supporting of loads over a variety of gaps for a variety of uses such as gaps for doors or windows.
Please note: The lintel will require an additional 150mm end bearing for each end of the lintel. For example: if the gap that needs to be covered is 1800mm then an extra 300mm will need to be added to the total length of the load bearing lintel.

This range of heavy duty load bearing lintels has been made from high quality pre-galvanised mild steel and satisfy the thermal performance requirements of England and Wales’ part L of the building regulations, Northern Ireland’s part F and Scotland’s technical handbook, section 6.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Please refer to the installation guide for further information.

The figures also take into account the different loading types which are common in traditional cavity wall construction. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003
Differential Total UDL kN 3:1 (up to 75% loading on the inner leaf)
Differential Total UDL kN 19:1 (up to 95% loading on the inner leaf)

Length (150mm increments)Height (mm)Steel Thickness (mm)Total UDL kN 3:1Total UDL kN 19:1
750 - 15001252.93020
1650 - 21001602.93022
2250 - 30001803.23530
3150 - 36001803.23025
3750 - 40502003.23026

HD/K-150 - Heavy Duty Load Bearing Cavity Wall Lintel

This heavy duty load bearing lintel is suitable for bearing heavier loads than a standard lintel and has been designed for use with cavity gaps between 150mm and 165mm. The lintel has an outer leaf width of 95mm but is able to support bricks with a width up to 102mm (95mm leaf width + 7mm overhang). The inner leaf has a width of 100mm and is able to support blocks of the same width.

The HD/K-150 heavy duty lintels are available in 150mm increments starting at 750mm up to 4050mm which allows for the supporting of loads over a variety of gaps for a variety of uses such as gaps for doors or windows.
Please note: The lintel will require an additional 150mm end bearing for each end of the lintel. For example: if the gap that needs to be covered is 1800mm then an extra 300mm will need to be added to the total length of the load bearing lintel.

This range of heavy duty load bearing lintels has been made from high quality pre-galvanised mild steel and satisfy the thermal performance requirements of England and Wales’ part L of the building regulations, Northern Ireland’s part F and Scotland’s technical handbook, section 6.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Please refer to the installation guide for further information.

The figures also take into account the different loading types which are common in traditional cavity wall construction. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003
Differential Total UDL kN 3:1 (up to 75% loading on the inner leaf)
Differential Total UDL kN 19:1 (up to 95% loading on the inner leaf)

Length (150mm increments)Height (mm)Steel Thickness (mm)Total UDL kN 3:1Total UDL kN 19:1
750 - 15001252.93020
1650 - 21001602.93022
2250 - 30001803.23530
3150 - 36001803.23025
3750 - 40502003.23026
Goods Total
Overall Quantity:
0
Total:
£0.00
£0.00
Total: £0.00